Meeting Banner
Abstract #5003

Resolving Phase: Inversion of SWI-Phase Data in Order to Obtain Its Sources Utilizing the Concept of a Generalized Lorentzian Approximation

Ferdinand Schweser1, Moritz Htten2, Berengar Wendel Lehr2, Andreas Deistung2, Daniel Gllmar2, Jrgen Rainer Reichenbach2

1Medical Physics Group, Department of Diagnostic and Interventional Radiology , Jena University Hospital, Jena, Germany; 2Medical Physics Group, Department of Diagnostic and Interventional Radiology, Jena University Hospital, Jena, Germany


Phase data acquired at multiple orientations with respect to the magnetic field was inverted to susceptibility, rotation-invariant local shift, and anisotropy-related susceptibility. Results indicate that gray-to-white matter contrast in phase images is dominated by sources from magnetic susceptibilities rather than macro-molecular exchange processes.