Highly Accelerated 3D MR Angiography Using Multi-Channel Blind Deconvolution

Peizhou Huang1, Jingyuan Lyu2, Hongyu Li3, Yongsheng Chen4,5, Saifeng Liu4, Chaoyi Zhang3, Ukash Nakarmi3, E. Mark Haacke4,5, and Leslie Ying1,3

1Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States, 2United-Imaging Healthcare America, Houston, TX, United States, 3Electrical Engineering, State University of New York at Buffalo, Buffalo, NY, United States, 4The MRI Institute for Biomedical Research, Detroit, MI, United States, 5Department of Radiology, Wayne State University, Detroit, MI, United States

In many clinical applications, the three dimensional (3D) MRA plays an important role because that the 3D MRA can provide plenty of details for more compact anatomic regions with various flow directions. However, the speed limitation of the 3D MRA reconstruction is still an unignorable problem due to the size of the dataset, especially when the dataset has multi channels. With our proposed method, the Multi-Channel Blind Deconvolution (MalBEC), the experiment demonstrate that this method can provide high quality reconstruction image with high acceleration factors using much less time.