Meeting Banner
Abstract #4365

MR imaging of the lung with a respiratory-gated ultrashort echo time (UTE) sequence with spiral acquisition technique: A feasibility study in oncology patients

Min Jae Cha1, Hyun Jeong Park1, Eun Sun Lee1, Sung Bin Park1, Yang Soo Kim1, and Byung In Choi1

1Department of Radiology, Chung-Ang University Hospital, Seoul, Republic of Korea

We have demonstrated the feasibility of respiratory-gated ultrashort echo time sequence with spiral acquisition technique (spiral UTE; 1.5-mm isotropic resolution; echo time, 0.05 msec) of the lung for pulmonary nodule detection in oncology patients. Overall nodule detection rate was 86% (43 of 50 nodules) and the detection rate for nodules of ≥5 mm was 100 % (20 of 20 nodules). Mean acquisition time for spiral UTE was 327 seconds (range, 300 – 465 seconds). We think that spiral UTE could be a potential alternative to chest CT in oncology patients, who are in the risk of inevitable radiation exposure.

This abstract and the presentation materials are available to members only; a login is required.

Join Here