Matteo Pavan1, Signe Johanna Vannesj1,
Christoph Barmet1, David Brunner1, Klaas Paul
Pruessmann1
1ETH
Frequency
Division Multiplexing has been used from engineers since a long time to carry
different signals in the same transmission line. The method consists to add
signals with non-overlapping frequencies content to each other. Each signal
can be fully recovered with passband filtering. In this work we use this
technique to acquire in the same spectrometer channel both image information
and magnetic-field-monitoring information. The image can be eventually
reconstructed taking into account the actual measured magnetic field dynamic.
Magnetic field monitoring is performed measuring the phase information in
four fluorine probe; with this method additional channels are not need.
Keywords