Clinical Feasibility of High-Resolution Navigator-Gated 3D T1w Hepatobiliary MRI with Gd-EOB-DTPA Enhancement

Alan De Lun Xu1, Anja C. Brau2, Yuji Iwadate2, Jarrett Rosenberg1, Shreyas Vasanawala1, Robert Herfkens1

1Radiology, Stanford University, Stanford, CA, United States; 2GE Healthcare


Conventional contrast-enhanced 3D T1w hepatic imaging requires serial breath-hold acquisitions to capture the contrast dynamics, inherently limiting spatial resolution and image quality. The hepatobiliary-specific contrast agent Gd-EOB-DTPA offers a prolonged time window of contrast-enhancement over which data can be acquired. This work evaluates the clinical feasibility of using a navigator-gated 3D T1w sequence to improve the spatial resolution and image quality of Gd-EOB-DTPA-enhanced hepatobiliary imaging compared to conventional breath-hold imaging.