Meeting Banner
Abstract #4468

MREIT & EPT: A Comparison of Two Conductivity Imaging Modalities

Dong-Hyun Kim1, Min-Oh Ghim1, Ohin Kwon2, Hyung Joong Kim3, Jin Keun Seo4, Eung Je Woo3

1Electrical & Electronic Engineering, Yonsei University, Seoul, Korea, Republic of; 2Mathematics, Konkuk University, Korea, Republic of; 3Biomedical Engineering, Kyung Hee University, Korea, Republic of; 4Mathematics, Yonsei University, Seoul, Korea, Republic of


Magnetic resonance electrical impedance tomography (MREIT) and MR electrical properties tomography (MREPT) are medical imaging modalities capable of visualizing the electrical permittivity and conductivity distribution of conducting objects at different operating frequencies. MREIT provides conductivity information at low frequency while MREPT is related to the conductivity at the Larmor frequency. Here both experiments are carried out to show the contrast differences in the two imaging methods.

Keywords