Meeting Banner
Abstract #1657

Variable Bandwidth Turbo Spin-Echo Dixon Imaging

Holger Eggers 1

1 Philips Research, Hamburg, Germany

The echo shifts commonly applied in turbo spin-echo Dixon imaging for chemical shift encoding affect the signal-to-noise ratio in the resulting in-phase and water images not only directly through the noise propagation in the water-fat separation, but also indirectly through the turbo spin-echo sequence. In this work, an optimization of the signal-to-noise ratio is proposed under the constraint of a fixed spacing between successive refocusing pulses. On the example of dual-echo Dixon imaging, it is shown to lead to shorter optimal echo shifts and to suggest a variable readout gradient strength, bandwidth and sampling window length per echo shift, which permits enhancing the signal-to-noise ratio.

How to access this content:

For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.

After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.