Abstract #0431

MR Fingerprinting with Chemical Exchange (MRF-X) for In Vivo Multi-Compartment Relaxation and Exchange Rate Mapping

Jesse Ian Hamilton1, Anagha Deshmane1, Mark Griswold1,2, and Nicole Seiberlich1,2

1Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States, 2Radiology, University Hospitals, Cleveland, OH, United States

MR Fingerprinting with Chemical Exchange (MRF-X) is presented for in vivo quantification of relaxation times, volume fraction, and exchange rate for tissues with two compartments. Data are presented in healthy volunteers in both brain and leg skeletal muscle and compared with previously reported measurements.