Meeting Banner
Abstract #3218

Effect of parallel imaging reference scan on fMRI evaluated at 7T.

Steen Moeller1, Sudhir ramanna1, Kamil ugurbil1, and Essa Yacoub1

1Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States

Investigation on the effect of reference or calibration scans needed to reconstruct undersampled MRI data. The study covers 3 different acceleration factors, and 6 different reference acquisitions. It is found that scan to scan variability for common acceleration factors is larger than any difference in tSNR between FLASH and FLEET, and that segmented EPI and single-shot are inferior to FLASH and FLEET acquisitions.

How to access this content:

For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.

After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.

After two years, the meeting proceedings (abstracts) are opened to the public and require no login information. Videos remain behind password for access by members, registrants and E-Library customers.

Click here for more information on becoming a member.

Keywords