3D liver R2, R2* and quantitative susceptibility maps in a single breath-hold

Chao Li1, Jiahao Li2, Jinwei Zhang2, Pascal Spincemaille3, Thanh Nguyen3, and Yi Wang3
1Applied and engineering physics, Cornell university, New York, NY, United States, 2Biomedical engineering, Cornell university, New York, NY, United States, 3Weill Cornell Medicine, New York, NY, United States

Synopsis

Keywords: Liver, Multi-ContrastIn this work, a 3D stack-of-spiral spoiled gradient echo sequence was implemented using T2 prepared single and multi-echo gradient echo acquisition for simultaneous R2, R2* and QSM mapping in a single breath hold within 24 secs.