Abstract #2296

Quantifying MR Properties of the Cirrhotic Liver Using Explanted Specimens

Marsh J, Tublin M, Chapman B
University of Pittsburgh

We present preliminary quantification of the MR properties of cirrhotic livers using explanted livers. Explanted livers were obtained from the OR and imaged prior to routine pathology processing. T1 and T2* values were quantified using spiral based GRE sequences. T2 was quantified using FSE techniques. Fat was measured using in-phase and out-of-phase GRE images. Good separation between HCC and surrounding cirrhotic tissue using T1 and Fat measures were obtained. T2 showed limited separation between HCC nodules and the cirrhotic tissue. T2* measures were not used due to blurring and distortion in the spiral images when long TE values were used.