Temporal Resolution and SNR Requirements for Accurate DCE-MRI Measurement of Microvascular Blood Flow and Permeability Using the AATH Model

Lucy Elizabeth Kershaw1, Hai-Ling Margaret Cheng1,2

1The Research Institute and Diagnostic Imaging, The Hospital for Sick Children, Toronto, Ontario, Canada; 2Department of Medical Biophysics, The University of Toronto, Toronto, Ontario, Canada


This simulation study investigated parameter accuracy for the AATH model, which allows separate measurements of flow and permeability. The influence of three key factors was assessed: temporal resolution, signal to noise ratio and error in the AIF peak height measurement. Results showed that a high temporal resolution is the most critical factor in ensuring parameter accuracy but this requirement can be relaxed if larger biases can be permitted and Tc need not be accurately measured. An error of 10 % in the measurement of the AIF peak height resulted in an error of at most 10 % in each parameter.