Coil Comparison for In Vivo Eye Imaging at 7T

Peter A. Wassenaar1, Kathryn Richdale2, Petra Schmalbrock1, Michael V. Knopp1

1Wright Center of Innovation, Department of Radiology, the Ohio State University, Columbus, OH, United States; 2College of Optometry, the Ohio State University, Columbus, OH, United States


Imaging of the human eye is important in the assessment of ocular diseases. With the introduction of eye imaging at 7T comes increased signal and higher resolution visualization of the orbit and ocular structures. This work compares different single loop receive coils for in vivo eye imaging at 7T. It is shown that a small custom-built coil provides the best approach for imaging the lens and ciliary body, while slightly larger coils are best suitable for imaging of the retinal wall and retro-bulbar structures.