Abstract #0886
Comparison of Non-rigid Motion Compensated Reconstructions for 3D Abdominal MRI
Gastao Cruz 1 , David Atkinson 2 , Christoph Kolbitsch 1 , Tobias Schaeffter 1 , and Claudia Prieto 1
1
Division of Imaging Sciences & Biomedical
Engineering, King's College London, London, United
Kingdom,
2
Centre
for Medical Imaging, University College London, London,
United Kingdom
We propose a motion compensation framework for 3D
free-breathing abdominal MRI. This approach uses a
general matrix description that incorporates motion
compensation directly into the reconstruction process.
The proposed method is compared with a recently
introduced motion compensation technique based on image
warping and the conventional gated approach. Results
show the proposed approach produces images sharper than
the image warping approach and gated reconstruction.