Abstract #3620
Quantitative Liver Function Analysis using T1 mapping with fast multi-slice B1 correction on Hepatocyte-specific contrast enhanced MR
Jeong Hee Yoon 1 , Jeong Min Lee 1 , Eun Ju Kim 2 , Tomoyuki Okuaki 3 , Joon Koo Han 1 , and Byung Ihn Choi 1
1
Radiology, Seoul National University
Hospital, Seoul, Seoul, Korea,
2
Philips
Healthcare Korea, Seoul, Seoul, Korea,
3
Philips
Healthcare Japan, Tokyo, Japan
The purpose of this study is to determine whether T1
mapping sequence with fast multi-slice B1 correction
shows better diagnostic performance than T1 mapping
without B1 correction, for estimating liver function on
Gd-EOB-DTPA enhanced MRI. Postcontrast T1 relaxation
times (R1) with B1 correction of the liver on
Gd-EOB-DTPA MRI were significantly different among
different C-P score groups: 427.8145.8 msec in A5;
502.5134.9 msec in A6; and 640.9370.8 msec in B7
(P<0.001). As for R1s of the liver without B1
correction, values were 375.9156.8 msec in A5;
338.382.8 msec in A6; and 565.2336.2 msec in B7. T1
mapping using VFA and B1 correction can be used for
quantitatively estimate liver function using hepatocyte-specific
contrast enhanced MRI.
How to access this content:
For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.
After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.
After two years, the meeting proceedings (abstracts) are opened to the public and require no login information. Videos remain behind password for access by members, registrants and E-Library customers.
Click here for more information on becoming a member.