The Feasibility of Meningeal Imaging using multi-echo gradient echo sequence mFFE with optimized scan parameters

Han Dou1, Xiaoming Wang1, Yang Zheng1, and Zhiwei Shen2
1Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China, 2Philips healthcare,Beijing,China, Beijing, China

Synopsis

At present, the detection of meningeal diseases is mainly based on MRI enhanced scan sequences, however, the poor image quality of affected the degree of meninges visualization due to the limited concentration of contrast agent staying in the meningeal after administration. In this study, the feasibility of meningeal imaging with multi-echo gradient echo MR sequence (Mffe) was explored, and optimized the main scan parameters. The optimal imaging parameters were obtained by analyzing the meninge-skull signal intensity ratio (SIR) and contrast-noise ratio (CNR) of healthy volunteers.