Meeting Banner
Abstract #0059

Dual-center repeatability and comparison of 3D phase-resolved functional lung (PREFUL) ventilation MRI at 3T

Filip Klimeš1,2, Chuan Tai Foo3,4, Marcel Gutberlet1,2, Andreas Voskrebenzev1,2, Richard McIntyre5,6, Marius Malte Wernz1,2, Robin Aaron Müller1,2, Robert Grimm7, Frank Wacker1,2, Frank Thien3,4, and Jens Vogel-Claussen1,2
1Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany, 2Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), Hannover, Germany, 3Department of Respiratory Medicine, Eastern Health, Melbourne, Australia, 4Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Australia, 5Monash Biomedical Imaging, Monash University, Melbourne, Australia, 6Monash Imaging Department, Monash Health, Melbourne, Australia, 7MR Application Predevelopment, Siemens Healthineers AG, Erlangen, Germany

Synopsis

Keywords: Lung, Lung, Repeatability

Motivation: 3D phase-resolved functional lung (PREFUL) MRI provides evaluation of ventilation during free-breathing without contrast agents. The repeatability of 3D PREFUL at 3T is unknown.

Goal(s): To assess the performance of 3D PREFUL in dual-center setting and to compare 3T measurement to 1.5T.

Approach: Dual-center 3D PREFUL MRI in healthy volunteers

Results: 3D PREFUL was feasible at 3T scanners at both centers. The repeatability assessments showed a bias only for one parameter, where it was negligibly small. Significant differences of 3D PREFUL ventilation parameters were observed between 1.5T and 3T, suggesting for pronounced susceptibility effects at 3T.

Impact: Despite the pronounced differences in ventilation parameters across the field strengths, consistently reproducible surrogates of ventilation markers were derived from 3D PREFUL MRI using a patient-friendly acquisition without the need for contrast agents and during free tidal breathing.

How to access this content:

For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.

After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.

After two years, the meeting proceedings (abstracts) are opened to the public and require no login information. Videos remain behind password for access by members, registrants and E-Library customers.

Click here for more information on becoming a member.

Keywords