Meeting Banner
Abstract #1207

Assessing Machine Learning Robustness in MRS Quantification: Impact of Training Strategies on Out-of-Distribution Generalization

Julian P. Merkofer1, Antonia Kaiser2, Anouk Schrantee3,4, Oliver J. Gurney-Champion3,5, and Ruud J. G. van Sloun1
1Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands, 2Center for Biomedical Imaging, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland, 3Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, Netherlands, 4Center for Urban Mental Health, University of Amsterdam, Amsterdam, Netherlands, 5Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, Netherlands

Synopsis

Keywords: Analysis/Processing, Spectroscopy, ML Robustness, MRS Quantification

Motivation: Despite promising developments, current machine learning methods for magnetic resonance spectroscopy (MRS) suffer from limited robustness and generalization issues, restricting their clinical application.

Goal(s): This study compares training strategies for MRS quantification, focusing on neural network resilience to out-of-distribution samples.

Approach: Bias towards the training distribution was assessed for various out-of-distribution cases in synthetic data and in-vivo data.

Results: Our findings reveal that, while common supervised regression is most accurate for in-distribution cases, it shows the most data bias; physics-informed self-supervised training is more robust; while integrating a least-squares fitting method within the training framework enhances standalone performance while remaining generalizable.

Impact: To advance integration in clinical MRS, robust and generalizable machine learning methods are needed. This study's exploration of quantification training strategies offers insights into data biases and advocates hybrid models that combine traditional methods with neural networks to maintain robustness.

How to access this content:

For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.

After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.

After two years, the meeting proceedings (abstracts) are opened to the public and require no login information. Videos remain behind password for access by members, registrants and E-Library customers.

Click here for more information on becoming a member.

Keywords