Keywords: Quantitative Imaging, Brain, Susceptibility, high-field, bSSFP
Motivation: Phase-cycled(PC) balanced steady-state free precession(bSSFP) sequences offer yet-to-be-explored capabilities for quantitative susceptibility mapping(QSM), T1, and T2 mapping, particularly attractive for 7T applications.
Goal(s): To determine the potential of PC-bSSFP for simultaneous QSM, T1 and T2 mapping in the brain at 7T.
Approach: PC-bSSFP-based off-resonance, tissue phase, T1 and T2 maps are compared with reference maps obtained from ME-GRE and MP2RAGE, in three subjects at 7T.
Results: PC-bSSFP-based off-resonance and tissue phase maps agreed with ME-GRE-based references with absolute mean errors of 13.2±3Hz and 8.9±3.7Hz, respectively. PC-bSSFP-based T1 and T2 maps matched the expected brain contrast with high precision.
Impact: At 7T, PC-bSSFP enables quantitative measurements of susceptibility, T1, and T2, within one acquisition, while providing high quality weighted images with a clear distinction between different brain structures.
How to access this content:
For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.
After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.
After two years, the meeting proceedings (abstracts) are opened to the public and require no login information. Videos remain behind password for access by members, registrants and E-Library customers.