Keywords: Tumors (Pre-Treatment), Arterial spin labelling
Motivation: Blood brain barrier arterial spin labeling (BBB-ASL) could assess BBB integrity. However, the assumption of homogeneous T2 in data fitting might be broken in gliomas.
Goal(s): To evaluate the BBB integrity in gliomas with regional tissue-specific T2.
Approach: A mono-exponential T2 fitting was used to obtain tissue-specific T2 values to estimate time of water exchange (Tex) and perfusion (CBF) in the tumor, normal-appearing white (NAWM), and gray matter (NAGM) using ExploreASL.
Results: Higher Tex in NAWM, and lower Tex in the tumor and NAGM were observed and the tumor heterogeneity was better depicted when tissue-specific T2 values were used.
Impact: Water exchange and perfusion maps are highly affected by the tissue T2 value used in BBB-ASL data processing. Applying tissue-specific T2 correction has resulted in a more reliable evaluation of BBB integrity in gliomas.