Motivation: Cardiac diffusion tensor imaging (cDTI) enables the characterization of the myocardial microstructural environment. However, B0 inhomogeneity around the heart can lead to EPI distortion and signal loss in cDTI.
Goal(s): To investigate the feasibility of using FSL TOPUP for EPI Distortion Correction in cDTI.
Approach: This proposed approach could be seamlessly integrated into cDTI postprocessing, significantly improving the accuracy and reproducibility of cDTI, particularly when researchers are analyzing metrics alongside other cardiac image parameters.
Results: The FSL TOPUP method could correct EPI distortion in both diffusion-weighted images (b0 and b400), following which kinds of cDTI metrics are reconstructed successfully after the correction.
Impact: The FSL TOPUP algorithm has been successfully integrated into the cDTI postprocessing in order to correct EPI distortion effectively.
How to access this content:
For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.
After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.
After two years, the meeting proceedings (abstracts) are opened to the public and require no login information. Videos remain behind password for access by members, registrants and E-Library customers.