Meeting Banner
Abstract #3827

Comparison of standardized uptake values in normal structures and breast cancer metastases using PET/CT and PET/MRI

Akshat C Pujara 1 , Carolyn Wassong 1 , Roy A Raad 1 , James Babb 1 , Linda Moy 1 , and Amy Melsaether 1

1 New York University School of Medicine, New York, NY, United States

Validation of MR attenuation correction (MRAC) is required for comparison of SUVs derived from PET/CT with those derived from PET/MRI. The current study demonstrates that SUVmax generated from MRAC correlates well with SUVmax generated from PET/CT for normal structures and breast cancer metastases, and can thus be used for quantification of FDG activity. Interestingly, the metabolic activity of breast cancer metastases during the interval between PET/CT and PET/MRI differed depending on the site of spread. Further investigation is needed to evaluate the potential role of SUV measurements in tailoring imaging protocols to the metabolic activity of organ-specific metastases.

How to access this content:

For one year after publication, abstracts and videos are only open to registrants of this annual meeting. Registrants should use their existing login information. Non-registrant access can be purchased via the ISMRM E-Library.

After one year, current ISMRM & ISMRT members get free access to both the abstracts and videos. Non-members and non-registrants must purchase access via the ISMRM E-Library.

After two years, the meeting proceedings (abstracts) are opened to the public and require no login information. Videos remain behind password for access by members, registrants and E-Library customers.

Click here for more information on becoming a member.

Keywords